Intelligent Frequency Converter Circulation Pump UPN

PERFORMANCE RANGE

●Max Flow: 10m³/h
●Max head: 8m

APPLICATION FIELDS

●It's designed for circulation of liquids in heating and air-conditioning systems,
air energy hot water circulation system,solar hot water circulation system, etc.

Classify:

Detail

 

A water pump is a mechanical device that transports or pressurizes liquids. It transmits the mechanical energy or other external energy of the prime mover to the liquid to increase the energy of the liquid. It is mainly used to transport liquid, including water, oil, acid-base liquid, emulsion, suspended lotion and liquid metal.
It can also transport liquids, gas mixtures, and liquids containing suspended solids. The technical parameters of water pump performance include flow rate, suction head, head, shaft power, water power, efficiency, etc; According to different working principles, it can be divided into types such as volumetric water pumps and vane pumps. A positive displacement pump utilizes changes in the volume of its working chamber to transmit energy; Vane pumps use the interaction between rotating blades and water to transfer energy, and there are various types of pumps, such as centrifugal pumps, axial flow pumps, and mixed flow pumps.

 

Intelligent Frequency Converter Circulation Pump  UPN

 

PUMP
●Pump body: Cast iron
●Impeller: PP

 

MOTOR
●Motor case: Aluminum
●100% Copper wire
●Bearing: Ceramic
●Shaft:Ceramic
●With thermal overload protector
●Insulation class:H
●Protection:IP44
●Continuous duty

 

Setting Pump Characteristics Curve Function 
AUTO Propotional pressure curve descending from highest to lowest The Autoadapt function automatically controls the pump performance within the specified
performance range. (1 )Adjusting pump performacne according to the system sizing; 
(2)Adjusting pump performance according to the variation of load history.When it comes to
autoadapt, the control mode of the pump is propotional pressure control. .
PP1 Min .propotional pressure curve  The operating performance point of the pump moves forward or backward along the minimum
propotional pressure curve, depending on the heat demand. The pressure of puma
decreases at falling heat demand and increases at rising heat demand.
PP2 Middle .propotional pressure curve The operating performance point of the pump moves forward or backward along the middle
propotional pressure curve, depending on the heat demand. The pressure of puma
decreases at falling heat demand and increases at rising heat demand. 
PP3 Max.propotional
pressure curve
The operating performance point of the pump moves forward or backward along the 
maximum propotional pressure curve, depending on the heat demand. The pressure of puma
decreases at falling heat demand and increases at rising heat demand.
CP1 Max. propotional
pressure curve
The operating performance point of the pump moves forward or backward along the
maximum propotional pressure curve, depending on the heat demand. The pressure of puma
decreases at falling heat demand and increases at rising heat demand.
CP2 Middle.constant
pressure curve 
Based on the heat demand of the system, the operating performance point of the pump
moves in or out the middle constant pressure curve. The pressure of the pump stays remain
irrespective of the flow.
CP3 Max. constant
pressure curve 
Based on the heat demand of the system, the operating performance point of the pump
moves in or out the maximum constant pressure curve. The pressure of the pump stays .
remain irrespective of the flow.
III Rate III The pump runs at certain speed and performs a constant curve. For rate川mode, it means
the pump performs the maximum curve under all operating conditions. To set the pump to
rate |I| mode for only a short period of time means rapid pump venting. 
II Rate II The pump runs at certain speed and performs a constant curve. For rate II mode, it means
the pump performs the medium curve under all operating conditions.
I Rate I The pump runs at certain speed and performs a constant curve. For rate I mode, it means the
pump performs the minimum curve under all operating conditions.
Img Img The night setback is automatic under certain conditions, where the pump runs with minimum
performance and energy consumption.

 

TECHNICAL DATE

Model Power(w) Voltage Max flow(m3/h) Max head(m) Dimensions(mm)
L H B DN1 DN
UPN25-8 8-125 220V/50Hz 7.5 8 180 137 90 1½" 1"
UPN32-8 8-125 7.5 8 180 137 90 2" 1¼"
UPN32-12 160 7 12 180 137 90 2" 1¼"
UPN25-12 160 7 12 180 137 90 1%" 1

 

The Intelligent Frequency Converter Circulation Pump is a cutting-edge solution designed to optimize fluid flow in heating, cooling, and industrial systems. By integrating advanced frequency conversion technology, this pump automatically adjusts its speed to match demand, ensuring energy efficiency and reduced operational costs. Its smart control system minimizes power consumption while maintaining consistent performance, making it ideal for both residential and commercial applications.

With its Intelligent Frequency Converter technology, this Circulation Pump delivers precise flow control, eliminating unnecessary energy waste. The pump’s ability to adapt to varying system requirements enhances longevity and reduces wear and tear. Whether used in HVAC systems, underfloor heating, or industrial processes, it ensures quiet operation and superior reliability.

The Intelligent Frequency Converter Circulation Pump stands out for its user-friendly interface and seamless integration with modern automation systems. Real-time monitoring and diagnostics provide actionable insights, enabling proactive maintenance and minimizing downtime. Its robust construction ensures durability even in demanding environments, offering a sustainable alternative to traditional fixed-speed pumps.

Upgrade to the Intelligent Frequency Converter Circulation Pump and experience unmatched efficiency, smart performance, and long-term savings. This innovative pump redefines fluid circulation by combining intelligence, adaptability, and eco-friendly operation. Invest in a smarter future with a pump that meets the highest standards of energy efficiency and reliability.

 

Message